Edlbi & Partners Engineering Industries
Shelter designed and constructed to live for at least 25 years under the conditions of the following environment: the rate of external temperature of -5 to 55 degrees Celsius. Humidity in the air a Shelter directly under the sun. Resistant to rain, dust and wind-up speed of 165 km / hr. Average internal temperature of 22 to 25 degrees Celsius
Consists of about roofing and walls of the following
  • Rolled sheets from the top to give a solid and beautiful form of the plate-based thermal insulation greased Mazibak against moisture.
  • POLYURETHANE foam heavily) 40-35 kg / m 3 (and the advantage of insulating properties of polyurethane adhesives are excellent when interacting and composed of polyurethane insulation) 97% (of gas freon) CO2 (does not contain any impurities).
  • Rolled sheets from the bottom to give a solid and beautiful form of the plate-based thermal insulation greased Mazibak against moisture.
  • There are multiple thickness of the foam insulation panels (40 -60 -100-80 mm), depending on demand.
  • Panels are nested with each other by a special nail of the same specification also "in a sandwich Pannell.
 

Shelter Measure

Height
Weidth
Length
Measure
Sample 1
2560 / 2850 mm
3000/2840 mm
4000/3840 mm
Internal / External Measure
Sample 2
2560/2850 mm
2840/3000mm
3000/2840 mm
Internal / External Measure
1980 mm
980 mm
Door Measure

It is possible to implement Shelters in different sizes at your request



The basic components of Shelter:

  • Prefabricated structure with the structure holder consisting of profiles and galvanized metal angles to the protector and by 80-65 microns as illustrated image.
  • Infrastructure removable and installation.
  • All metal parts processing Balglvinp the protector 80-65 microns.
  • Structure and all metal parts in the structure linked with each other by bolts to form a metal cage with each other constantly resistant to weather and wind.
  • In case there are workshops uploaded a special lift.
The umbrella of the door:
Is an umbrella for a door which is a sheet of galvanized iron sheet of a suitable length and a sleek geometric thickness sheet (1 mm).
Umbrella over the room:
To ensure better protection from the sun is the second installation of a roof of a room where is placed sheets of tin rolled Mazibak basis and the status of slash to the possibility of storm water and is installed by a strong and resistant to wind and the roof covering the first insulation material to prevent leakage of rain into the room and this umbrella is designed to withstand the weight status of 150 kg / m 2 and weight of snow.
General specifications for doors:

Doors Shelter consists of the following main elements:
- Exoskeleton (Almbann): The framework consists of the hard outer section of the aluminum that has several broad rubber gaskets to prevent leakage of any light or air from inside and abroad.
- Chapter Mobile: consists of aluminum door mobile broadband also "and has several rubber gaskets to give the door a high thermal insulation.
- Filling the door: the door charge is made up of a wooden frame thickness (2.5 cm) from both sides, clothing Besaj greased heat "and filler material is injected foam insulation.
-Lock the door: The door lock installation Uribe made a special for this section of the door with a long tongue to give a sense of security against any attempt to steal can open the door from within by Shelter caught him in particular.

Gaskets:
used Palmbann and the door gaskets are specific to that section made from raw materials of high quality flexible to give a high capacity of the insulation.

Notes
  • All components Shelter galvanized the protector as the thickness of galvanizing (80-65 microns or less ") to small parts, and nuts and Kalpraghi Altbachim .. etc..
  • The interrelation between the parts and components are Shelter by bolts.
  • Provides Shelter degree at the door measurement (110 * 40 cm) (above the ground by) 10 cm.
Materials that are installed within the Shelter: Entrance cables, control panel generally within Shelter, vacuum plate fuses, panel fire alarm, fire sensor, smoke sensor, bearer of cables offer / 30 cm / Shelter within the four walls, a roof lighting is impervious to Mpteyn provider private key of / / 2, a socket internal power of / / 2, sensitive to the special section, the number of thermostat heat / / 2, the emergency lighting device, a belt of copper grounding measurement / 0,5 × 3 cm / copper bar measuring / 1 × 10 × 30 cm /, Club Lighting, external provider a private key.
Amendments to the Shelter: Can Shelter amendment to the base to be installed 6 meters above the Mast Shelter engineered careful and considered approach to the weight of mast with all the accessories that are installed on the mast of the antennas and showers.
Transportation and installation: There are special workshops manufactured on the back of Shelter to download Shelter on the back of trucks for the possibility of lifting Shelter by telescopic cranes in upland areas of the land.
 
Copyright © dalYlak.com